Air return duct

Air return duct systems can be configured in two ways: each room can have a return duct that sends air back to the heating and cooling equipment, or return grills can be located in central locations on each floor. For the latter case, either grills must be installed to allow air to pass out of closed rooms, or short "jumper ducts" can be installed to connect the vent in one room with the next, allowing air to flow back to the central return grilles. Door undercuts help, but are usually not sufficient for return airflow.
You can perform a simple check for adequate return air capacity by doing the following:
  1. Close all exterior doors and windows
  2. Close all interior room doors
  3. Turn on the central air handler
  4. "Crack" interior doors one by one and observe if the door closes or further opens "on its own." (Whether it closes or opens will depend on the direction of the air handler-driven air flow.) Rooms served by air-moved doors have restricted return air flow and need pressure relief as described above